|'''[[Rain barrels]]'''
|'''[[Rain barrels]]'''
|Not applicable
|Not a constraint
||Not applicable||Not applicable||1||0||NA||Yes||None||Yes||None
||Not applicable||Not a constraint||1||0||NA||Yes||None||Yes||None
|-
|-
|'''[[rainwater harvesting|Cisterns]]'''
|'''[[rainwater harvesting|Cisterns]]'''
|Not applicable
|Not a constraint
|Not applicable||Not applicable||0||0||0||Yes||None||Yes||None
|Not applicable||Not a constraint||0||0||0||Yes||None||Yes||None
|-
|-
|'''[[Downspout disconnection|Roof downspout disconnection]]'''
|'''[[Downspout disconnection|Roof downspout disconnection]]'''
|Not applicable
|Not a constraint
|4:1 or less||Amend if < 15 mm/hr||0.5||5 to 20||1 to 5||Yes||Building Foundation||Yes||None
|4:1 or less||Decompact if < 15 mm/hr||0.5||5 to 20||1 to 5||Yes||Building Foundation||Yes||None
|-
|-
|'''[[Infiltration trenches]] or [[Infiltration chambers]]'''
|'''[[Infiltration trenches]] or [[Infiltration chambers]]'''
Line 32: Line 32:
|-
|-
|'''[[Bioretention]]'''
|'''[[Bioretention]]'''
|1 (infiltrating); Not applicable (non-infiltrating)
|1 (infiltrating); Not a constraint (non-infiltrating)
|5:1 to 15:1||[[Underdrain]] recommended<br>if < 15 mm/hr||1 to 2||5 to 10||0 to 2||No (infiltrating); Yes (non-infiltrating)||4m- Building Foundation<br>Underground Utilities, Trees,<br>Drinking Water Wellhead<br>Protection Areas||No (infiltrating); Yes (non-infiltrating)||2 yr (infiltrating); None (non-infiltrating)
|5:1 to 15:1||[[Underdrain]] recommended<br>if < 15 mm/hr||1 to 2||5 to 10||0 to 2||No (infiltrating); Yes (non-infiltrating)||4m- Building Foundation<br>Underground Utilities, Trees,<br>Drinking Water Wellhead<br>Protection Areas||No (infiltrating); Yes (non-infiltrating)||2 yr (infiltrating); None (non-infiltrating)
|-
|-
|'''[[Stormwater planters]]'''
|'''[[Stormwater planters]]'''
|Not applicable
|Not a constraint
|5:1||Not a constraint||1 to 2||2 to 5||0 to 2||No (infiltrating); Yes (non-infiltrating)||Building Foundation, Trees||No (infiltrating); Yes (non-infiltrating)||2 Yr (infiltrating); None (non-infiltrating)
|5:1||Not a constraint||1 to 2||2 to 5||0 to 2||No (infiltrating); Yes (non-infiltrating)||Building Foundation, Trees||No (infiltrating); Yes (non-infiltrating)||2 Yr (infiltrating); None (non-infiltrating)
|-
|-
|'''[[Vegetated filter strips]]'''
|'''[[Vegetated filter strips]]'''
|Not applicable
|Not a constraint
|5:1||Amend if < 15 mm/hr||0 to 1||15 to 20||1 to 5||No||None||Yes||None
|5:1||Decompact if < 15 mm/hr||0 to 1||15 to 20||1 to 5||No||None||Yes||None
|-
|-
|'''[[Permeable pavements]]'''
|'''[[Permeable pavements]]'''
Line 49: Line 49:
|'''[[Enhanced swales]] (featuring check dams)'''
|'''[[Enhanced swales]] (featuring check dams)'''
|1  
|1  
|5:1 to 10:1||Amend if < 15 mm/hr||1 to 3||5 to 15||0.5 to 6||No||4m- Building Foundation<br>Underground Utilities||No||2 Yr
|5:1 to 10:1||Decompact if < 15 mm/hr||1 to 3||5 to 15||0.5 to 6||No||4m- Building Foundation<br>Underground Utilities||No||2 Yr
|-
|-
|'''[[Bioswales]] (Dry swales)'''
|'''[[Bioswales]] (Dry swales)'''

Navigation menu