Line 349: |
Line 349: |
|
| |
|
| ===Finishing Grades: Inlet, Outlet, Biomedia, Plants (JC)=== | | ===Finishing Grades: Inlet, Outlet, Biomedia, Plants (JC)=== |
| '''As-built Survey'''<br>
| | {{:As-built surveys} |
| Throughout the construction process, it is sometimes necessary to deviate from the intended design of LID features and adapt the design to on-site conditions. The completion of a post-construction as-built survey is a standard operating procedure for engineering projects that captures and changes that were made to the feature’s design during construction.
| |
| | |
| Survey Steps:
| |
| *Use the same datum as the pre-engineering survey
| |
| *If a pre-engineering survey is not available, use a reference feature as the datum
| |
| *Include data on critical feature elevations and existing utilities, such as:
| |
| **Inverts of newly installed pipe
| |
| **Vertical and horizontal bends in pipes
| |
| **Existing public utilities
| |
| **Existing private utilities
| |
| **New and existing structures (e.g. catchbasins, manholes, chambers, etc.)
| |
| *Identify the type, diameter, and material of exposed utilities
| |
| | |
| Inspection Points:
| |
| *Datum matches the pre-engineering survey or selected reference feature
| |
| *Data provided in as-built survey matches the as-built standards of the City
| |
|
| |
|
| ===Address Deficiencies and Assumption Protocols (JC)=== | | ===Address Deficiencies and Assumption Protocols (JC)=== |