'''Construction Steps:'''
'''Construction Steps:'''
#Ensure joint pattern and width match drawing details. According to the American Concrete Institute (ACI) 522-IM-13 standard, “minimum joint width for saw cutting is 3 mm”.
#Ensure joint pattern and width match drawing details. According to the [https://cecollection2.files.wordpress.com/2020/05/522.1-13-specification-for-pervious-concrete-pavement.pdf American Concrete Institute (ACI) 522-IM-13 standard], “minimum joint width for saw cutting is 3 mm”.
#Cut the joints on the pervious concrete surface immediately after the concrete is rolled/compacted.
#Cut the joints on the pervious concrete surface immediately after the concrete is rolled/compacted.
#Alternatively, sawcut concrete after concrete has solidified enough to avoid removing aggregate material from the concrete pavement.  
#Alternatively, sawcut concrete after concrete has solidified enough to avoid removing aggregate material from the concrete pavement.  