Line 22: |
Line 22: |
| *''P<sub>d</sub>'' = The daily demand per person (L) | | *''P<sub>d</sub>'' = The daily demand per person (L) |
| *''n'' = The number of occupants}} | | *''n'' = The number of occupants}} |
| | |
|
| |
|
| Then the following calculations are based upon two criteria: | | Then the following calculations are based upon two criteria: |
Line 27: |
Line 28: |
| #The average annual demand (D) is greater than the average annual yield (Y) from the catchment. | | #The average annual demand (D) is greater than the average annual yield (Y) from the catchment. |
|
| |
|
| *When \(0.33<Y_{0.05}/D_{0.05}<0.7\), the storage volume required can be estimated:
| | When \(0.33<Y_{0.05}/D_{0.05}<0.7\), the storage volume required can be estimated: |
| <math>V_{S} = A \times C_{vol,E}\times R_{d} \times e</math> | | <math>V_{S} = A \times C_{vol,E}\times R_{d} \times e</math> |
| Where: | | Where: |
Line 37: |
Line 38: |
| *''e'' = The efficiency of the pre-storage filter.}} | | *''e'' = The efficiency of the pre-storage filter.}} |
|
| |
|
| *Careful catchment selection means that the runoff coefficient, for a rainstorm event (C<sub>vol, E</sub>) should be 0.9 or greater. | | |*Careful catchment selection means that the runoff coefficient, for a rainstorm event (C<sub>vol, E</sub>) should be 0.9 or greater. |
| | | |
| When 0.33 < Y<sub>0.05</sub>/ D<sub>0.05</sub>< 0.7, the total storage required can be estimated by adding Y<sub>0.05</sub>: | | When 0.33 < Y<sub>0.05</sub>/ D<sub>0.05</sub>< 0.7, the total storage required can be estimated by adding Y<sub>0.05</sub>: |