Changes
Jump to navigation
Jump to search
← Older edit
Newer edit →
Infiltration: Sizing and modeling
(view source)
Revision as of 16:01, 7 September 2017
4 bytes added
,
7 years ago
→One dimensional infiltration
Line 45:
Line 45:
<h3>Drawdown time</h3>
<h3>Drawdown time</h3>
The design of infiltration facilities should be checked for [[drawdown time]]. Target drawdown time is between 48-72 hours.
The design of infiltration facilities should be checked for [[drawdown time]]. Target drawdown time is between 48-72 hours.
<br>
To calculate the time (''t'') to fully drain the facility:
To calculate the time (''t'') to fully drain the facility:
<math>t=\frac{nd}{q}</math>
<math>t=\frac{nd}{q}</math>
Jenny Hill
Bureaucrats
,
Administrators
,
Widget editors
8,254
edits
Navigation menu
Personal tools
English
Log in
Namespaces
Page
Discussion
Variants
expanded
collapsed
Views
Read
View source
View history
More
expanded
collapsed
Search
Navigation
Home
Table of contents
All pages
Recent changes
Responses to comments
Tools
Special pages
Printable version