The surface storage volume of a dry pond (''A<sub>p</sub>'') is determined:
The surface storage volume of a dry pond (''A<sub>p</sub>'') is determined:
   
   
<math>A_{p}=\frac{RVC_T\times A_{c}}{f'\times t_{drawdown}}</math>
<math>A_{p}=\frac{RVC_T\times A_{c}}{f'\times t}}</math>


{{Plainlist|1=Where:
{{Plainlist|1=Where:
Line 15: Line 15:
*''A<sub>c</sub>'' = Area of the catchment (m<sup>2</sup>)
*''A<sub>c</sub>'' = Area of the catchment (m<sup>2</sup>)
*''f''' = design infiltration rate (mm/hr)
*''f''' = design infiltration rate (mm/hr)
*''t'' = [[drawdown time]] (hrs)}}
*''t'' = [[drainage time|time permitted for ponding to infiltrate]] (hrs)}}


----
----