Dry ponds
(view source)
Revision as of 20:06, 7 March 2018
5 bytes removed
,
6 years ago
m
→Sizing
Line 13:
Line 13:
The surface storage volume of a dry pond (''A<sub>p</sub>'') is determined:
The surface storage volume of a dry pond (''A<sub>p</sub>'') is determined:
<math>A_{p}=\frac{RVC_T\times A_{c}}{f'\times t}</math>
<math>A_{p}=\frac{RVC_T\times A_{c}}{f'\times t}</math>
{{Plainlist|1=Where:
{{Plainlist|1=Where:
*''RVC<sub>T</sub>'' = [[Runoff volume control target]] (mm)
*''RVC<sub>T</sub>'' = [[Runoff volume control target]] (mm)
Line 19:
Line 18:
*''f''' = design infiltration rate (mm/hr)
*''f''' = design infiltration rate (mm/hr)
*''t'' = [[drainage time|time permitted for ponding to infiltrate]] (hrs) (typically 48 hours)}}
*''t'' = [[drainage time|time permitted for ponding to infiltrate]] (hrs) (typically 48 hours)}}
----
==Excess flow control==
==Excess flow control==