==Design==
==Design==
1. The required volume for a forebay (''V<sub>f</sub>'', m³) serving catchments up to five hectares, may be calculated as:  
1. The required volume for a forebay (''V<sub>f</sub>'', m³) serving catchments up to five hectares may be calculated as:  


:<math>V_{f}=A_{c}\times R\times L_{o} \times F_{c}</math>
:<math>V_{f}=A_{c}\times R\times L_{o} \times F_{c}</math>