Changes

Jump to navigation Jump to search
m
Line 49: Line 49:
*Step 1: Determine what the planting needs are and assign appropriate depth of media, using the table above.  
*Step 1: Determine what the planting needs are and assign appropriate depth of media, using the table above.  
*Step 2: Select an underdrain pipe diameter (typically 100 - 200 mm), assign this as an 'embedding' depth. *Note that this component does not apply if a downstream riser is being used.   
*Step 2: Select an underdrain pipe diameter (typically 100 - 200 mm), assign this as an 'embedding' depth. *Note that this component does not apply if a downstream riser is being used.   
*Step 3: Calculate the maximum possible storage reservoir depth beneath the pipe (''d<sub>s, max</sub>''):
*Step 3: Calculate the maximum possible storage reservoir depth beneath the pipe (''d<sub>s, max</sub>'', mm):
<math>d_{s, max}=\frac{f'\times t}{0.4}</math>
<math>d_{s, max}=\frac{f'\times t}{0.4}</math>
{{Plainlist|1=Where:
{{Plainlist|1=Where:

Navigation menu