==Size a bioretention cell for constrained depth==
==Size a bioretention cell for constrained depth==
{{float right| {{:Depth to GW}}}}
{{float right| {{:Depth to GW}}}}
If there is a constraint to the depth (''d<sub>T</sub>'', m) of the infiltration practice, calculate the required footprint area (''A<sub>p</sub>'', m<sup>2</sup>), as:
If there is a constraint to the depth (''d<sub>T</sub>'', m) of the practice, calculate the required footprint area (''A<sub>p</sub>'', m<sup>2</sup>), as:
<math>A_{p}=\frac{A_c\times i\times D}{(V_{R}\times d_{T})+(f'\times D)}</math>
<math>A_{p}=\frac{A_c\times i\times D}{(V_{R}\times d_{T})+(f'\times D)}</math>
{{Plainlist|1=Where:
{{Plainlist|1=Where: