|Filter media Plant-Available Phosphorus > 40 ppm||Filter media Plant-Available Phosphorus < 40 ppm
|Filter media Plant-Available Phosphorus > 40 ppm||Filter media Plant-Available Phosphorus < 40 ppm
|-
|-
|Filter media predominantly sand||Filter media contains fractions of fines and organic material in sand
|Filter media is predominantly sand||Filter media is a mixture of sand, topsoil and organic material
|-
|-
|Surface covered with stone (or uncovered)||Surface covered with mulch and dense vegetation
|Surface covered with turf grass and stone||Surface covered with mulch and dense, deeply rooting vegetation
|}
|}


===Sizing and Modelling===
===Sizing and Modelling===
Bioretention facilities should be sized to accommodate runoff from approximately 10 to 20 times the footprint area of the facility. i.e. they should have an I/P ratio of 10 to 20.  
Bioretention facilities should be sized to accommodate runoff from approximately 5 to 20 times the footprint area of the facility. i.e. they should have an I/P ratio of 5 to 20.  
When the drainage area is too large, silt can accumulate very rapidly, overwhelm the [[pretreatment]] devices, and lead to clogging of the facility.  
When the drainage area is too large, silt can accumulate very rapidly, overwhelm the [[pretreatment]] devices, and lead to clogging of the facility.  
When the drainage area is relatively small compared to a bioretention facility, it can make the facility appear unreasonably costly.   
When the drainage area is relatively small compared to a bioretention facility, it can make the facility unreasonably costly.   
*'''[[Bioretention: Sizing| Sizing]]'''
*'''[[Bioretention: Sizing| Sizing]]'''
*'''[[Bioretention: TTT| Modelling]]'''
*'''[[Bioretention: TTT| Modelling]]'''
Line 87: Line 87:
*A [[gravel diaphragm]] for sheet flow
*A [[gravel diaphragm]] for sheet flow
*[[Vegetated filter strips]] for sheet flow
*[[Vegetated filter strips]] for sheet flow
*A [[Forebays|forebay]] for concentrated overground flow
*A [[Forebays|forebay]] for concentrated surface flow
*An [[Oil and grit separators|oil and grit separator]] for concentrated underground flow
*An [[Oil and grit separators|oil and grit separator]] for concentrated underground flow