*The configuration of the outflow was also an important consideration. In systems where the outlet is elevated above the native soil, runoff reduction levels tend to be considerably higher than systems with underdrains located at the native soil interface, even if outflow rates from the non-elevated drains are controlled by orifices or flow control valves. | *The configuration of the outflow was also an important consideration. In systems where the outlet is elevated above the native soil, runoff reduction levels tend to be considerably higher than systems with underdrains located at the native soil interface, even if outflow rates from the non-elevated drains are controlled by orifices or flow control valves. |